Deficiency vs. Recommendation in NFPA 25 Inspection Reporting

Ahern FP Service Tech

The National Fire Protection Association (NFPA) 25 standard is a critical document for the inspection, testing, and maintenance of water-based fire protection systems. It ensures that these systems are reliable and ready to perform in the event of a fire. Within the context of NFPA 25, understanding the distinction between a deficiency and a recommendation is essential for accurate reporting and effective maintenance.

Deficiency: Identifying Non-Compliance

A deficiency in NFPA 25 inspection reporting refers to any condition in a fire protection system that does not comply with the standard’s requirements. Deficiencies are critical issues that must be addressed to ensure the system’s proper operation and compliance with safety regulations. These can include:

  • Physical Damage: Visible damage to pipes, sprinklers, or other components that could impair system functionality.
  • Obstructions: Any blockage that could prevent the proper distribution of water during a fire.
  • Corrosion: Rust or other forms of corrosion that weaken system components.
  • Improper Installation: Components that are not installed according to NFPA 25 standards or manufacturer specifications.
  • Inadequate Water Supply: Insufficient water pressure or volume to meet the system’s design requirements.

Deficiencies must be documented in the inspection report and typically require immediate corrective action. The urgency of addressing deficiencies is due to their potential impact on the system’s ability to control or extinguish a fire, thereby posing a significant risk to life and property.

Recommendation: Enhancing System Performance

Recommendations, on the other hand, are suggestions for improvements that go beyond the minimum requirements of NFPA 25. While not mandatory, these recommendations can enhance the performance, reliability, and longevity of the fire protection system. Examples of recommendations include:

  • Upgrading Components: Replacing older components with newer, more efficient models.
  • System Enhancements: Adding features such as additional sprinklers or advanced monitoring systems.
  • Preventive Maintenance: Implementing a more rigorous maintenance schedule to prevent future deficiencies.
  • Training: Providing additional training for personnel responsible for system maintenance and operation.

Recommendations are often based on best practices and the inspector’s professional judgment. While they are not required for compliance, implementing these suggestions can provide added safety benefits and potentially reduce long-term maintenance costs.

Addressing Deficiencies and Implementing Recommendations

Addressing deficiencies should always be the top priority, as these issues directly impact the system’s compliance and functionality. Once deficiencies are resolved, facility managers can consider implementing recommendations to further enhance system performance.

Regular inspections and timely maintenance are key to ensuring that fire protection systems remain in optimal condition. By understanding and acting on both deficiencies and recommendations, building owners can maintain compliance with NFPA 25 and ensure the safety of occupants and property.


In summary, the distinction between deficiencies and recommendations in NFPA 25 inspection reporting is vital for maintaining effective fire protection systems. Deficiencies indicate non-compliance and require immediate action, while recommendations suggest improvements that can enhance system performance. Clear reporting and proactive maintenance are essential for ensuring that fire protection systems are always ready to perform when needed. By addressing both deficiencies and recommendations, facility managers can uphold safety standards and protect lives and property.

Whether or not we performed the original installation, Ahern can service and keep your fire protection systems fully operational. Contact us today to schedule your next inspection.